Title |
Experiment Study on Reduction of CO2 Concentration with Indoor Plant through the Occurrence Patterns of CO2 |
Authors |
Oh Geun-Sug ; Jung Gun-Joo ; Im Young-Bin |
Keywords |
Indoor Plant ; Indoor Air Quality ; Occurrence Pattern of Carbon Dioxide(CO2) ; Office |
Abstract |
The purpose of this study was investigating the reduction effects of Carbon Dioxide(CO2) with the indoor plant(IP) through the conditions same as real world. First of all, we conduct literature review and measurement survey to suggest the occurrence pattern of CO2 in office. And then we apply the occurrence pattern of CO2 like an actual office on small chamber test. This experiment condition was different from the precedent studies which fix the initial concentration of CO2(1000ppm). Because the condition of occurrence pattern of CO2 was continually increase in the actual office. The result of this study was following. IPs will do better reduction of CO2 under the occurrence pattern of CO2 has steadily increased every time. In other words, we expect that the effect of IPs to reduce contaminant in real world is more effective than the precedent studies. |