Mobile QR Code QR CODE
Export citation EndNote
Title Seismic Performance Evaluation of 3 Story OMRCF Based on Scaled Model Testing
Authors 한상환 ; 권건업
Page pp.673-678
ISSN 1229-5515
Keywords 보통모멘트골조 ; 내진설계 ; 밑면전단력 ordinary moment resiting concrete frame ; seismic design ; base shear
Abstract ACI 318 (1999) defines three types of moment frames: Ordinary Moment Resisting Concrete Frame (OMRCF), Intermediate Moment Resisting Concrete Frame (IMRCF), and Special Moment Resisting Concrete Frame (SMRCF). OMRCF is the most popular type of moment frame in mild seismic zones that requires the least detail and design requirements. This study focuses on the seismic performance of Ordinary Moment Resisting Concrete Frames (OMRCF) designed only for gravity loads. For this purpose a 3-story OMRCF was designed in compliance with the minimum design requirements in ACI 318 (1999). An one third 3 story specimen was made and tested. For scaled model, the similitude law of true replica was applied. The specimen was loaded with quasi-static reversed cyclic lateral loading. The overall behavior of OMRCF is quite stable without abrupt strength degradation. It is found that tested frame has the base shear strength larger than the design base shear for seismic zone 1, 2A and 2B calculated using UBC 1997.