Mobile QR Code QR CODE
Export citation EndNote
Authors 장극관 ; 천영수 ; 김동영
Page pp.975-982
ISSN 1229-5515
Keywords 면진 ; 적층고무형 면진 장치 ; 철근콘크리트 건물 ; 진동대 base isolation ; laminated rubber bearing ; reinforced concrete building ; shaking table test
Abstract Scientific community agrees about the fact that base Isolation provides interesting solutions to minimize the seismic risk. Reliability of such a technique is nowadays proofed by a large number of applications like public buildings, nuclear plants, bridges, etc. This paper reports the results of performance verification tests of the base isolated RC building with the laminated rubber bearings which is manufactured by enterprise in Korea. The shaking table tests were performed using a three story model scaled to 1/3 of the prototype RC apartment building. Several major earthquake records were scaled to different peak ground accelerations and used as input base excitations. Especially in this study, effect of earthquake characteristics on response reduction and effect of the intensity of excitations are studied. Through the verification tests, the validity of the applied base isolaion device and the response reduction effect against earthquakes are confirmed