Title |
Seismic Performance Preliminary Evaluation Method of Reinforced Concrete Apartments with Bearing Wall system
|
Keywords |
내진설계규정 ; 내진 성능 ; 벽식 구조 공동주택 ; 전단응력 ; 층간 변위 지수 |
Abstract |
In Korea, the seismic design regulations was established since 1988 about regularity scale of structures. However, It was not established about seismic performance and evaluation method as the most existing buildings was constructed before Earthquake-Resistant Design(1988). In this study, for model structures which are 4 units of non-seismic designed apartment and 3 units of seismic designed in Korea performed seismic performance evaluation by suggested KISTC (2004). And the result compare to evaluate Capacity Spectrum Method by using MIDAS Gen and SDS. As a result, we observed that suggested KISTC's method have overestimated for shear stress and drift index. The purpose of this study provides most conformity seismic performance evaluation process and the appropriate method of calculating the seismic performance index in Korea.
|