Title |
Experimental Study on the Shear Strength of Form Tie Connector Linked by Stud Coupler
|
Keywords |
지하합성벽 ; 전단연결재 ; 폼타이 basement composite wall ; shear connector ; form tie |
Abstract |
In general, conventional sheeting H-pile is often used as a temporary member installed upon construction of outer retaining wall at basement floor. In CBW (composite basement wall), R/C basement wall is combined with H-Pile and resists lateral soil pressure together. This paper presents an experimental results of push out shear test of CBW with stud coupler as shear connectors to combine H-Pile with R/C wall six specimens with different diameter of FT (form tie) and arrangement of shear connectors were tested to evaluate the shear capacity of the composite wall. Test results showed that shear strength increased with diameter of FT. The shear strength of shear connector in CBW could be suitably predicted by using the previous equations codified in the codes. Best corelation, especially, was found when the calculation result by the formula in AISC 360-05 was compared to test one.
|