Mobile QR Code QR CODE
Export citation EndNote
Title An Experimental Study on the Influence of High Fineness Fly Ash and Water-Binder Ratio on Properties of Concrete
Authors 이상수 ; 송하영 ; 이승민
Page pp.29-35
ISSN 1229-5515
Keywords 3성분계 콘크리트 ; 플라이애쉬 ; 유동성 ; 수화열 ternary system concrete ; fly ash ; fluidity ; heat of hydration
Abstract Recently, the press and institute recognized fly ash as it had excellent performance. Its research and applications are on the rise largely as a substitute for cement. On the contrary, it is in a situation that the regulation of high fineness fly ash remains at a low level. As for the fly ash in 3,000~4,500 cm2/g class fineness regulated in KS L 5405, it is used by substituting it around the unit weight of cement 20%. Accordingly, the regulation in upper classification is in a situation of being insufficient. Therefore, this study aimed to establish 4000, 6000, and 8000 class of fineness of fly ash and three levels of substitute like 15%, 30%, and 45% in order to analyze the substitute and effect of water-binder ratio for fly ash that affected the properties of ternary system concrete. As a result of experiment by planning water-binder ratio for two levels like 40% and 50%, the more replacement ratio and fineness of fly ash increased in the performance not hardened, the more the fluidity increased. This study has found out that the air content decreased, and that there was setting acceleration and it decreased the heat of hydration. In addition, as for the strength properties in a state of performance hardened concrete, the more the replacement ratio and the ratio of water-binding materials increased, the more it had a tendency of being decreased.