Title |
Flexural Behavior of Prestressed Dual Concrete Beams
|
Keywords |
고성능 강섬유 보강 콘크리트 ; 프리스트레스트 이중 콘크리트 보 ; 휨 거동 해석 high performance steel fiber reinforced concrete ; prestressed dual concrete beams ; analysis of flexural behavior |
Abstract |
Cracks due to low tensile strength in prestressed concrete (PC) beams may decrease rigidity and structural performance, resulting in excessive deflection. In an effort to solve this problem, in this research, prestressed dual concrete (PDC) has been proposed, consisting of normal strength concrete in compression zone, and high performance steel fiber reinforced concrete(HPSFRC) with a partial depth in tensile zone. Three PDC beams with different depths of HPSFRC and two PC beams were cast for experiments. Analytical models at each stage, i.e., precracking, postcracking, and ultimate, were proposed for analysis of flexural behavior in PDC beams. The experimental results agree well to the analytical ones. Crack formation and its propagation are controlled by the HPSFRC in PDC beams. The initial cracking and service limit loads are increased along with the load carrying capacity and flexural stiffness.
|