Mobile QR Code QR CODE
Export citation EndNote
Title Shear and Bond Strength of Activated Hwangtoh Concrete Beam
Authors 이남곤 ; 박홍근 ; 황혜주
Page pp.685-694
ISSN 1229-5515
Keywords 활성 황토 ; 전단 강도 ; 부착 강도 activated Hwangtoh ; shear strength ; bond strength
Abstract As a eco-friendly material, Hwangtoh (red clay) has been studied for complete or partial replacement of portland cement. Most of existing studies focused on the material properties of the Hwangtoh concrete including the compressive strength, drying shringkage, and creep. In the present study, the shear strength of the beams made with the Hwangtoh concrete was tested. Further, bond strength of tension re-bars embedded in the Hwangtoh concrete was tested. One of the concrete tested consisted of activated Hwangtoh replacing 20% of the cement. The other consisted 100% activated. Hwangtoh replacing all the cement. The beam specimens were tested under two point static loading. The test result showed that the shear strength of activated Hwangtoh concrete beams replacing 20% and 100% of cement was equivalent to that of the ordinary portland cement concrete beam. However, the bond strength of activated Hwangtoh concrete replacing 100% of the cement was less than that of the ordinary portland cement concrete.