Title |
An Experimental Study on the Performance of Bond-Type Anchorage Systems with Various Dimensions of Steel Mold
|
Keywords |
CFRP ; tendon ; 정착 ; 부착형 ; 채움재 carbon fiber reinforced polymer ; tendon ; anchoring ; bond-type ; filler |
Abstract |
This paper contains the experimental performance evaluation results of bond-type anchorage systems with the CFRP(carbon fiber reinforced polymer) tendon. The preliminary tests were performed to find the appropriate filling materials in the steel molds. A total of five materials including epoxy or cement mortar have been used as fillers in the steel molds. Results of the preliminary tests showed that specimen filled with non-shrinkage mortar showed maximum tensile strength. Based on the finding, the non-shrinkage mortar was selected as filler for anchoring CFRP tendons. Additional tests were performed as a parametric study to select proper size of steel molds such as external diameter, thickness, and length. The proper size of steel molds with non-shrinkage mortar was selected based on the test results, which gave stable tensile performance.
|