Mobile QR Code QR CODE
Export citation EndNote
Title Experimental Verification on the Structural Safety of Cantilever Beam Connected with Post-installed Adhesive Anchor Bolts
Authors 오홍섭 ; 박성락
Page pp.529-536
ISSN 1229-5515
Keywords 내민보 ; 부착식 후설치 앵커 볼트 ; 프리스트레싱 ; 확장 보도부 cantilever beam ; post installed adhesive anchor bolt ; prestressing ; expanded sidewalk
Abstract Recently, there has been a growing interest in expanded sidewalks for existing bridges. The cantilever beam system applied to expanded sidewalks for existing bridges are connected with the concrete structure by adhesive anchor bolts. However, the extended sidewalks are currently constructed without standardized regulations, which lead to excessive design of the beam spacing and installation and the construction difficulties due to the excessive over-weight. Moreover, there is only limited analysis and experiment data on the post-installed adhesive anchor bolts, so the excessive number of bolts is used for the connection. This paper deals with a method to increase the effectiveness of beam sections and anchor bolts geometry for expanded sidewalk of existing bridge. The study results showed that the failure of cantilever beam connected by adhesive anchor bolts was dominated by bond failure of interface between concrete and bolt. Also, the results indicated the possibilities of improving serviceability as well as safety of the sidewalks by changing of beam section and prestressing the bolts.