Title |
Seismic Performance of Beam-Column Connections for Special Moment Frame Using 600 MPa Flexural Reinforcement
|
Authors |
황현종 ; 박홍근 ; 최원석 ; 정란 ; 김진근 |
Keywords |
RC 보-기둥 접합부 ; 고강도 철근 ; SD600 ; 내진성능 실험 RC beam-column joint ; high strength reinforcement ; SD600 ; seismic performance test |
Abstract |
An experimental study was performed to evaluate the seismic performance of beam-column connections using 600 MPa re-bars for beam flexural reinforcement. Three full scale specimens of interior beam-column connection and two specimens of exterior beam-column connection were tested under cyclic loading. The specimens were designed to satisfy the requirements of Special Moment Frame according to current design code. The structural performance of the specimens with 600 MPa re-bar were compared with that of the specimen with 400 MPa re-bars. The test results showed that bond-slip increased in the beam-column joint. However, the load-carrying capacity, deformation capacity, and energy dissipation capacity of the specimens with 600 MPa re-bar were comparable to those of the specimens with 400 MPa re-bars.
|