Title |
Crack Source location Technique for nam Concrete Beam using Acoustic Emission
|
Keywords |
Felicity effect AE기법; 균열발생원; 카이저효과; 펠리시티효과; acoustic emission; crack source location; Kaiser effect |
Abstract |
This study was conducted preliminarily to develop the crack source location technique for plain concrete beam using acoustic emission(AE). Before the main experiment, the test of virtual An source location was achieved in plain concrete block. The sensor layout was mutually compared between triangular layout and rectangular layout. As the results of test, AE source location by triangular layout was evaluated more effective than that by rectangular layout. The specimen to apply he source location technique was man in total nine specimens (each three in 40 %, 50%, 60% of W/C ratio) which the experiment variable was the compressive strength level(W/C ratio). The bending loading method is selected by cyclic loadings to evaluate the degree of concrete damage. It is seen that Kaiser effect and Felicity effect exists through analysis of AE parameters in coming failure experiment. As a result of analyzing the felicity ratio(FR) values, it is shown that this values can be used for evaluating the degree of concerto damage. AE activity is started highly at the 70% of failure load without the compressive strength level. Thus considered by a index in constructing the system of the failure warning at application of the field structure. And the results compared the real cracking location with the source location has perceived by AE monitoring before it is appeared the primary crack by visual observation.
|