Title |
Bonding Properties of Epoxy-Concrete Interface in RC Beams Strengthened by Steel Plate
|
Keywords |
부착; 보강; 에폭시-콘크리트 계면; 강판; Mohr-Coulmb 규준; bonding; strengthening; epoxy-concrete interface; steel plate; Mohr-Coulomb criterion |
Abstract |
Both strength and stiffness of RC structures strengthened by a steel plate greatly increase and however, their ductility might not be sufficient because premature failures usually occur at the adhesive-concrete interface. In this study, Mohr-Coulomb criterion was adopted to examine the bonding failure mechanism, and the diagonal shear bonding test, the direct shear bonding test, and the flexural test on RC beams strengthened by a steel plate were carried out to measure the bonding properties. It is found from the experimental and numerical results that the cohesive strengths of epoxy-concrete interfaces are ranging from 50 kgf/㎠ to 70 kgf/㎠ when the friction angle is 45°. Bonding failure loads can be predicted by applying the bonding properties to the structural analysis of RC beams strengthened by steel plate. By considering them in the design of strengthened beams, the premature failure would be effectively prevented.
|