Title |
Tensile Behavior of Stud Bolt Connections
|
Authors |
이태석 ; 김승훈 ; 서수연 ; 이리형 ; 홍원기 |
Keywords |
스터드 접합; 보강근비; 인장강도; 접합상세; 강도감소계수; stud connection; reinforcement ratio; tensile strength; connection detail; strength reduction factor |
Abstract |
This paper presents the tensile behavior of stud connections installed between reinforced concrete and steel members. Eight specimens are tested to verify the factors influencing the tensile behavior of the connection. Major variables considered in the test are the reinforcement ratios of concrete member and connection details. Test results indicate that the reinforcing bars near stud bolts contribute to the increase of the tensile strength of the member as well as to the reduction of brittle failure. It is shown that C-type or U-type connection has relatively high ductility. From the evaluation on the tensile strength of test results including those of peformed by previous researchers, it was shown CCD (Concrete Capacity Design) method overestimated the strength. In this paper, the reduction factor of 0.75 ø instead of ø is suggested for design purpose of the stud connection.
|