Mobile QR Code QR CODE
Export citation EndNote
Title Seismic Performance of Special Shear Wall Structural System with Effectively Reduced Reinforcement Detail
Authors 천영수 ; 이기학 ; 이효원 ; 박영은 ; 송진규
DOI https://doi.org/10.4334/JKCI.2013.25.3.271
Page pp.271-281
Keywords 특수전단벽 ; 특수경계요소 ; FEMA P695 ; 주기하중재하 실험 ; 동적증분해석(IDA) special shear wall ; special boundary element ; FEMA P695 ; cyclic loading test ; incremental dynamic analysis
Abstract The current seismic design code prescribes that a structural wall should be designed as a special shear wall when the building height is more than 60 m and its seismic design category is classified as D. However, the use of a special shear wall has a negative effect on constructability and economic efficiency. In the present study, the seismic performance of a special shear wall and a special shear wall with relaxed reinforcement detail was evaluated through a cyclic reversal loading test. The specimens were constructed to measure the results of the experimental variable regarding the reinforcement details of the special boundary element. Next, the seismic performances of a special shear wall structural system and that of a special shear wall structural system with relaxed reinforcement detail was evaluated by methods proposed in the FEMA P695. The cyclic reversal loading test results of this study showed that the performance of the shear wall with relaxed reinforcement detail was almost similar to the performance of a special shear wall and has the performance which requested from standard. The results of the seismic evaluation showed that all special shear walls with relaxed reinforcement detail are satisfied with the design code and seismic performance.