Experiment of Flexural Behavior of Reinforced Concrete Beams with High Volume Fly Ash
|
DOI |
https://doi.org/10.4334/JKCI.2014.26.3.323 |
Keywords |
하이볼륨 ; 플라이애쉬 ; 휨거동 ; 성능평가 high volune ; fly ash ; flexural behavior ; performance evaluation |
Abstract |
It is known that the best way to recycle fly ash is to use in concrete. It is impossible to bury in the ground this fly ash recently, so it is trying to use high volume fly ash concrete. Nevertheless, recent main research topics are focused in the part of material only, however, it is necessary to perform the researches about elasticity modulus, stress-strain relationship and structural behavior. Therefore, in this paper, 18 test members were manufactured with 3 test variables, namely fly ash replacement ratio 0, 35, 50%, concrete compressive strength 20, 40, 60 MPa and 2 tensile steel ratio. 18 test members were tested for flexural behavior. From the test results, there were no differences between 35, 50% high volume fly ash cement concrete and ordinary concrete without fly ash(FA=0%).
|