Title |
Evaluation on the Mechanical Properties of Carbon Fiber Rebar for Substitution of Steel Rebar
|
Authors |
한성민(Sungmin Han) ; 이승윤(Seung-Yun Lee) ; 김선희(Sun-Hee Kim) ; 최원창(Wonchang Choi) |
DOI |
https://doi.org/10.4334/JKCI.2023.35.2.169 |
Keywords |
탄소보강근; 역학적성질; 인장강도시험; 압축강도시험; 전단강도시험 arbon fiber reinforced polymer rebar; mechanical properties; tensile strength test; compressive strength test; shear strength test |
Abstract |
Tensile strength test, compressive strength test, and shear strength test were conducted to confirm the mechanical properties of a prototype carbon fiber reinforced polymer (CFRP) rebar. As a results of the tensile strength test, the tensile strength of ACI 440.1R was satisfied. The compressive strength was confirmed to be 307 MPa, and the shear strength was 475 MPa. In addition, as a result of comparing the relationship between the tensile strength and the shear strength of the CFRP rebar, it was confirmed that the coefficient was slightly higher than in a previous study.
|