Mobile QR Code QR CODE
Export citation EndNote
Title Seismic Performance Evaluation of Precast Concrete Beam?Column Ductile Connections with Simplification Transverse Reinforcement Details Using Steel Fiber Reinforcement
Authors 정희진(Hee-Jin Jeong) ; 이문석(Moon-Seok Lee) ; 김문희(Moon-hee Kim) ; 손동희(Dong-Hee Son) ; 최창식(Chang-Sik Choi) ; 배백일(Baek-Il Bae)
DOI https://doi.org/10.4334/JKCI.2026.38.5.611
Page pp.611-619
ISSN 1229-5515
Keywords 프리캐스트 콘크리트; 연성접합부; 강섬유 보강 콘크리트; 내진 성능; 횡보강근 상세 완화 precast concrete; ductile connection; steel fiber-reinforced concrete; seismic performance; simplification of transverse reinforcement
Abstract This study evaluated the seismic performance of precast concrete (PC) ductile beam?column connections incorporating steel fiber-reinforced concrete (SFRC). Three full-scale beam-column joint specimens were fabricated and tested: a cast-in-place RC specimen, a PC control specimen, and a 2 % SFRC specimen with 50 % reduced transverse reinforcement. The 2 % SFRC specimen demonstrated superior performance, exhibiting a higher peak load, greater initial stiffness, and improved displacement ductility ratios (2.92-3.34) relative to the control specimens. Steel fibers effectively suppressed joint cracking and concrete spalling throughout cyclic loading. All specimens satisfied the ACI 374.1 acceptance criteria, confirming that 2 % SFRC can replace conventional transverse reinforcement while maintaining seismic performance.