Title |
Structural Behavior of Precast Concrete Intermediate Wall with Various Vertical Joint Details
|
|
Authors |
서수연(Soo-Yeon Seo) ; 문정호(Jeong-Ho Moon) ; 오영훈(Yeong-Hun Oh) ; 윤현도(Hyun-Do Yun) |
|
DOI |
https://doi.org/10.4334/JKCI.2026.38.5.665 |
|
Keywords |
수직접합부; 전단보강근 상세; PC 중간구조벽; 이력거동; 횡력실험 vertical joint; shear reinforcement details; precast concrete (PC) intermediate wall; hysteretic behavior; lateral force test |
|
Abstract |
In this study, in order to investigate the hysteretic behavior of precast concrete (PC) intermediate structural walls according to the shear reinforcement details of the vertical joint, repeated lateral force tests were conducted. on PC walls with three details of horizontal reinforcement within the vertical joint: conventional loop reinforcement, loop reinforcement rotated 90°, and head reinforcement confined by spiral reinforcement. The results showed that, regardless of the detail of the vertical connection, all specimens exhibited similar failure patterns and hysteretic responses, with displacement ratios at maximum strength of approximately 1 %. The vertical connection with head reinforcement confined by spiral reinforcement showed the highest strength and reinforcement efficiency. All three details were found to satisfy the performance requirements of PC intermediate structural walls specified by current Korean standards.
|