Title |
Layout Criteria of an Access Mode's on and off Facility at Multiple Transfer Centers |
DOI |
https://doi.org/10.12652/Ksce.2012.32.2D.095 |
Keywords |
복합환승센터;승하차시설;시설배치기준;가중평면환산거리 Transfer centers;on and off facility;layout criteria;a weighted average distance |
Abstract |
Layout Criteria are developed for an access mode's on and off facility at multiple transfer centers in this paper. Layout Criteria are location issues between a main mode and access modes in terms of the on and off facility one another. The total distance between them has been suggested to be minimized. In the distance calculation stairs are considered to be more difficult and than open space. On the other hand an escalator and an elevator are treated as easier than open space. Considering the number of people between on and off facility, the weighted average distance is suggested to be a MOE(Measure of effectiveness) for layout criteria at multiple transfer centers. Finally, the layout criteria are applied to the existing Kimpo airport terminal and some improvement ideas are suggested. |