Title |
Experimental Studies on PSC Airpit-Slab with Fire Resistance Panel under Static and Dynamic Loads |
Authors |
김태균(Kim, Tae Kyun) ; 배정(Bae, Jeong) ; 최헌(Choi, Heon) ; 민인기(Min, In Gi) |
DOI |
https://doi.org/10.12652/Ksce.2012.32.4A.245 |
Keywords |
터널;횡류식 환기시스템;PSC 풍도슬래브;내화패널;재하시험 tunnel;transverse ventilation system;psc airpit-slab;fire resistance panel;loading test |
Abstract |
In the longway tunnel and underground traffic road, the structure of transverse ventilation system is constructed by the airpit slab. In this study, the full scale specimens of the PSC airpit slab that attached fire resistance panel are performed the static and dynamic loading tests for evaluation of bending capacity. The first of all, it confirmed the evaluations about the fundamental efficiency of the fire resistance panel and PSC slab by the 3-point bending test and pull-off test. The tests are performed for evaluation of the bending resistance under ultimate static load and the bonded capacity under dynamic fatigue load. A fatigue test is performed for an investigation of the effect on wind pressure that is developed by transit of traffic. The damage or debonding on surface between fire resistance panel and PSC slab was not developed in dynamic fatigue load test, also the behavior of the specimens is very stable and the debonding of the fire resistance panel attached at the bottom surface of PSC slab was not developed in static load test, too. Therefore, the crack or debonding of the fire resistance panel will be not developed by external loads during the construction or completion of the precast fire resistance system. |