Mobile QR Code QR CODE : Journal of the Korean Society of Civil Engineers
Title Evaluation on Field Applicability of Cast-In-Place Pile using Surfactant Grout
Authors 도진웅(Do, Jinung) ; 김학승(Kim, Hakseung) ; 박봉근(Park, Bonggeun) ; 이주형(Lee, Juhyung)
DOI https://doi.org/10.12652/Ksce.2016.36.1.0075
Page pp.75-83
ISSN 10156348
Keywords 차수벽;계면활성제;흙막이벽체공법;수중불분리제 Cut-off wall;Surfactant grout;CIP;Antiwashout admixture
Abstract In case of underground construction affected by groundwater, CIP (Cast-In-Place Pile) method is generally used to resolve the geo-hydraulic problem. However, as this method has poor connectivity between piles, an auxiliary method for cut-off is needed in many cases. In this study, a new concept earth retaining wall method (H-CIP) with no auxiliary method, by using surfactant grout (Hi-FA) which improves antiwashout and infiltration ability, is introduced, and its field applicability is evaluated. CIP and H-CIP piles were installed with same ground conditions, and field and laboratory tests were conducted to verify the performance. As results, newly contrived H-CIP method shows higher field performance for cut-off and strength than conventional CIP method.