Mobile QR Code QR CODE : Journal of the Korean Society of Civil Engineers
Title On Vortex Reduction Characteristics of Pump Sump Circulating Water Intake Basin of Power Plant Using Hydraulic Experiment
Authors 엄중현(Eom, Junghyun) ; 이두한(Lee, Du Han) ; 김형수(Kim, Hung Soo)
DOI https://doi.org/10.12652/Ksce.2022.42.6.0815
Page pp.815-824
ISSN 10156348
Keywords 순환수 취수부; 와류; 와류제어장치; 커튼월; 컬럼 커튼월 Circulation water intake basin; Vortex; Anti vortex device; Curtain wall; Column curtain wall
Abstract Among the main facilities of the power plant, the circulating water used for cooling the power generation system is supplied through the Circulation Water Intake Basin (CWIB). The vortexes of various types generated in the Pump Sump (PS) of CWIB adversely affectthe Circulation Water Pump (CWP) and pipelines. In particular, the free surface vortex accompanied by air intake brings about vibration, noise, cavitation etc. and these are the causes of degradation of CWP performance, damage to pipelines. Then powergeneration is interrupted by the causes. Therefore, it is necessary to investigate the hydraulic characteristics of CWIB through the hydraulic model experiment and apply an appropriate Anti Vortex Device (AVD) that can control the vortex to enable smoothoperation of the power plant. In general, free surface vortex is controlled by Curtain Wall (CW) and the submerged vortex is by the antivortex device of the curtain wall. The detailed specifications are described in the American National Standard for Pump Intake Design. In this study, the circulating water intake part of the Tripoli West 4×350 MW power plant in Libya was targeted, the actual operating conditions were applied, and the vortex reduction effect of the anti vortex device generated in the suction tank among the circulating water intake part was analyzed through a hydraulic model experiment. In addition, a floor splitter was basically applied to control the submerged vortex, and a new type of column curtain wall was additionally applied to control the vortex generated on the free surfaceto confirm the effect. As a result of analyzing the hydraulic characteristics by additionally applying the newly developed Column Curtain Wall (CCW) to the existing curtain wall, we have found that the vortex was controlled by forming a uniform flow. In addition,the vortex angle generated in the circulating water pump pipeline was 5° or less, which is the design standard of ANSI/HI 9.8,confirming the stability of the flow.