Title |
Characteristics of Advanced Wastewater Treatment Process Using High MLSS in Anoxic Tank |
Authors |
손동훈 ( Son Dong Hun ) ; 임봉수 ( Im Bong Su ) ; 박혜숙 ( Park Hye Sug ) |
Keywords |
Advanced Wastewater Treatment Process; Nutrient Removal; Wasting Sludge Reduce |
Abstract |
This study was accomplished to develope an advanced wastewater treatment process using high MISS in anoxic tank aimed to improve nutrient removal and to reduce wasting sludge. It was operated with 4 Modes with varing solid concentration and internal recycle ratios. Mode Ⅰ, Ⅱ, Ⅲ was operated 1.0 - 1.5% MLSS concentration at anoxic tank with 50% sludge recycle rate, however, each internal recycle rate were 100%, 200%, 300% and Mode Ⅵ was operated 1.5 - 2.0% MLSS concentration at anoxic tank with 50% sludge recycle rate and 100% internal recycle rate. The COD removal efficiency didn`t show any big difference from Mode Ⅰ to Ⅵ. The average COD removal rate was over than 90%. The T-N removal rate was 73%, the highest rate in all mode. The 36% of SCOD is used for the denitrification and phosphorus release in the anoxic tank. Specific denitrification rate was 3.5㎎ NO₃^(-)-N/g M v h and denitrification time was 0.7hr. As MLSS concentration is higher in anoxic tank as denitrification time would be shorter. The T-P removal rate was average 70%. The phosphorus release accomplished from the anoxic tank because the anaerobic condition was prevalent in the anoxic due to the prompt completion of denitrification. Sludge production was 0.28 ㎏VSS/㎏ BOD_(removed) under the 1.5% MLSS and 17 day SRT. It is prominent result which has 40% sludge reduce comparing with traditional activate sludge system. |