The Journal of
the Korean Society on Water Environment

The Journal of
the Korean Society on Water Environment

Bimonthly
  • ISSN : 2289-0971 (Print)
  • ISSN : 2289-098X (Online)
  • KCI Accredited Journal

Editorial Office

Title Oxygen Transfer Efficiencies of A Single Spiral Roll Aeration System by the Off-gas Method
Authors 박보화 ( Bo Hwa Park ) ; 고광백 ( Kwang Baik Ko ) ; 박재한 ( Jae Han Park ) ; 임세호 ( Se Ho Lim ) ; 신동록 ( Dong Rok Shin ) ; 윤혜정 ( Hye Jung Yun ) ; 이지영 ( Ji Young Lee ) ; 문태호 ( Tae Hoon Moon )
Page pp.534-539
ISSN 2289-0971
Keywords Aeration system; Off-gas analyzer; OTE; OUR; SOTE
Abstract The supply of oxygen for aeration is the largest energy consumer at activated sludge wastewater treatment plants. Replacement of less efficient aeration systems with fine pore aeration devices can save up to 50 percent of aeration energy costs. The purpose of this study was the diagnosis and evaluation of a domestic wastewater aeration system by the off-gas method which had been studied by US EPA and ASCE. For this study, an off-gas analyzer and its hood were made to collect off-gas. Also, a vacuum pump was connected to the analyzer to make suction of off-gas. Experiments were conducted at a domestic activated sludge wastewater treatment plant which had a single spiral roll aeration system installed with P.E tube diffuser. Data on OTE(f), SOTE(pw), OUR, and air flow rate were obtained from these experiments. In case of replacing an aeration system, it is recommended that it should be replaced with perforated membrane disc or ceramic disc fine bubble diffusers installed in a full floor coverage or grid pattern.