Title |
A Study on the Performance Improvement of Flash-Mixer in Water-Treatment Plant |
Authors |
조인준 ( In Jun Cho ) ; 오상한 ( Sang Han Oh ) ; 이상욱 ( Sang Wook Lee ) ; 손창호 ( Chang Ho Son ) ; 정의준 ( Wui Jun Chung ) |
Keywords |
CFD; Field-data; Flow-Ratio; Mixing-Efficiency; Mixing-Strength; Zeta-Potential |
Abstract |
In results of accomplishing fundamental study to improve the flocculant-mixing of the Flash-Mixer in Onsan Water-Treatment Plant at the small cost, We obtained 8.9% of mixing-efficiency from the field data and 3.2% of the characteristic flow-ratio as the available maximum volume-ratio in this Water-Treatment Plant. The optimum elements with the deflector diameter of 400 mm and deflector angle of 145° at the flow ratio of 3.2% could be obtained from the expanded study on the ground of the fundamental study. Finally, the efficiency could be improved about 510% from 8.9% to 45.4% and the average turbidity could be improved about 14%. |