Title |
Determination of Design Capacity for NPS Pollutant Treatment Facilities by Long-term Simulation in Urban Areas |
Authors |
주진걸 ( Jing Gul Joo ) ; 유도근 ( Do Guen Yoo ) ; 김중훈 ( Joong Hoon Kim ) |
Keywords |
Long-term simulation; Non-point source pollutant; SWMM; Treatment |
Abstract |
In this study, a method to determine the design capacities of nonpoint source (NPS) pollutant treatment facilities in urban areas was suggested. A facility capacity to treat 80 percent of total SS discharge was estimated by 2-year rainfall-runoff-build-up and wash-off simulation at Goonja drainage district in Seoul. For wash-off simulation, four wash-off models (EMC, RC, EXP, and Joo model) were used. As the results, 80 percent of total SS discharge could be treated with only 7.7~31.4% facility capacity of peak flow. The suggested method and results will provide a guideline to determine design capacities of NPS pollutant treatment facility in urban areas. |