Current issue

Home > 2016-12

Download
Title Study on Characteristics of Radon Concentration and Effective Dose at Public Buildings in Korea
Authors Joon-sig Jung ; Ju-hee Yoo ; Kyu-sun Lee ; Jae-won Lee ; In-Keun Shim ; Soo-yun Seo ; Boo-wook Kim ; Myung-hee Kwon
Coverage
(Cover Date)
Vol.23 No.6(2016-12)
Keywords Radon ; Public building ; Seasonal radon concentration ; Province
Abstract The purpose of this study was to survey radon concentration and to evaluate radon annual effective dose in public buildings. We investigated 351 public buildings using alpha-track detector between January 2008 and May 2009. The concentration of indoor radon concentration for public building was 52.6±33.1 Bq/m3 (GM: 46.6 Bq/m3), and the range (min-max) was 15.2 to 317.7 Bq/m3. The indoor radon concentration for all public buildings were far below the recommended standards of IAQ Guideline, Ministry of Environment Korea. Indoor radon concentration of the C.B Province (AM: 70.0±53.2, GM: 58.7 Bq/m3) is higher than other Province. Also, Except for J.J Province, radon concentration at winter-season higher than that of the other seasons (spring, summer, autumn), respectively (p<0.01). The annual effective indoor radon dose was 0.37mSv/y, this values not exceed recommended standards of ICKL. This study will provide useful data for the determination of radon management and reduction at the public buildings.