Current issue

Download
Title
Authors Han Chang and Lee Inhee
Coverage
(Cover Date)
Vol.26 No.3(2019-06)
Keywords Northwestern China; Village house; Passive design; Thermal performance; Insulation material
Abstract Due to energy crisis and environment problems around the world, not only cities but also villages should con- centrate on the energy saving strategy and environment protection. Northwestern China is in the northwest area of China with large amount of rural population. Less considered passive design on the village house in northwestern China influ- ences life quality of rural people in northwestern China. XiAn is a typical city in northwestern China. Passive design strategy on typical village house in XiAn is analyzed in this research. There are mainly two types village house in XiAn; one type is traditional adobe house and the other type is new brick house. This research achieved two significances. The first one is that thermal performance between traditional adobe house and new brick house is compared. Results shows that traditional village house has better thermal performance than the new village house. The second significance of this research is that passive deign strategy on typical village house in XiAn is analyzed from house orientation, structure, insu- lation of the envelope, window to wall ratio and sunroom effect. Analysis results shows that each passive design strategy has its effect to improve the thermal performance of the village house.