Mobile QR Code QR CODE
Export citation EndNote
Title Investigation of Seismic Behavior of Low-Rise Piloti Structure according to Seismic Design and Base Isolation of Columns
Authors 정현진(Hyun-Jin Jung) ; 이상화(Sanghwa Lee) ; 김세호(Seho Kim) ; 안효준(Hyojoon An) ; 이종한(Jong-Han Lee)
DOI https://doi.org/10.4334/JKCI.2021.33.3.271
Page pp.271-278
ISSN 1229-5515
Keywords 필로티 구조물; 내진설계; 면진장치; 고유치해석; 지진응답 piloti; seismic design; isolation device; eigenvalue analysis; seismic response
Abstract The number of earthquakes in Korea is gradually increasing, and recent earthquakes in Gyeongju and Pohang caused serious damage to piloti structures, a common structural type in Korea. Therefore, this study evaluated the seismic safety of a piloti structure following seismic reinforcement of hoop rebar and the design of a column isolation device. The isolation device was designed at the bottom and also at the top of a column in consideration of repair and replacement. Eigenvalue analysis showed little difference in natural frequency according to the seismic design of hoop rebar but a reduction in the first natural frequency by approximately 15~21 % with the installation of the isolation device. The maximum displacement also decreased by approximately 20~22 % and the maximum stress by 43~73 %, depending on the position of the installed device. Compared with seismic reinforcement of the piloti structure with hoop rebar, the isolation device absorbed displacement induced by an earthquake within its allowable range, which results in simultaneously reducing structural displacement and the seismic load transmitted to the structure.