Mobile QR Code QR CODE
Export citation EndNote
1 
1.ACI T1.1R-01, “Commentary on Acceptance Criteria for Moment Frames Based on Structural Testing,” ACI Manual of Concrete Practice, ACI, 2002, pp. 1-7.Google Search
2 
2.Paulay, T. and Priestley, M. J. N., Seismic Design of Reinforced Concrete and Masonry Buildings, A Wiley Insterscience Publication, 1992, pp. 250-263.Google Search
3 
3.Ha, S. S., Kim, S. H., Moon, J. H., and Lee, L. H., “An Experimental Study on the Structural Behavior of the half PC Beam-Column Interior Joint with Strand,” Journal of Architectural Institute of Korea (AIK), Vol. 23, No. 9, 2007, pp. 3-11.Google Search
4 
4.Restrepo, J. I., Park, R., and Buchanan, A. H., “Test on Connections of Earthquake Resisting Precast Reinforced Concrete Perimeter Frames of Buildings,” PCI Journal, Vol. 40, No. 4, 1995, pp. 44-61.Google Search
5 
5.Abdel-Fattah, B. A. and Wight, J. K., “Study of Moving Beam Plastic Hinging Zones for Earthquake Resistiong Design of RC Buildings,” ACI Structural Journal, Vol. 84, No. 1, 1987, pp. 31-39.Google Search
6 
6.Choi, H. K., Yoo, C, H,, Choi. Y. C., and Choi, C. S., “Structural Capacity Evaluation of Hybrid Precast Concrete Beam-Column Connections Subjected to Cyclic Loading,” Journal of the Korea Concrete Institute, Vol. 22, No. 3, 2010, pp. 325-333. (doi: http://dx.doi.org/10.4334/JKCI.2010. 22.3.325)Google Search
7 
7.Choi, H. K., Choi. Y. C., and Choi, C. S., “Hysteretic Behavior and Seismic Resistant Capacity of Precast Concrete Beam-to-Column Connections,” Earthquake Engineering Society of Korea (EESK), Vol. 14, No. 4, 2010, pp. 61-71.DOI
8 
8.Hawileh, R., Rahman A., and Tabatabai, H., “Nonlinear Finite Element Analysis and Modeling of a Precast Hybrid Beam-Column Connection Subjected to Cyclic Loads,” Applied Mathematical Modelling, Vol. 34, No. 9, 2010, pp. 2562-2583.DOI
9 
9.Priestley, M. J. N., “Overview of PRESSS Research Program,” PCI Journal, Vol. 36, No. 4, 1991, pp. 50-57.Google Search
10 
10.Camarena, D., “Finite Element Analysis of Precast Prestressed Beam-Column Concrete Connection in Seismic Construction,” Chalmers University of Technology, Master’s Thesis, 2006.Google Search
11 
11.Han, T. S., Feenstra, P. H., and Illington, S. L., “Simulation of Highly Ductile Fiber-Reinforced Cement- Based Composite Components Under Cyclic Loading,” ACI Structural Journal, Vol. 100, No. 6, 2003, pp. 749-757.Google Search
12 
12.ABAQUS Theory Manual: Karlsson & Sorensen, Inc.Google Search
13 
13.Lee, J. and Fenves, G. L., “Plastic-Damage Model for Cyclic Loading of Concrete Structures,” Journal of Engineering Mechanics, Vol. 124, No. 8, 1998, pp. 892-900. (doi: http://dx.doi.org/10.1061/(ASCE)0733-9399(1998)124:8(892))Google Search
14 
14.Mittelstädt, J., Numerical Studies on Composite Action with Concrete Filled Hollow Section Columns, Studienarbeit of TUHH Matr. Nr. 30978, 2008, pp. 7-12.Google Search
15 
15.NZS 3101: Part 1, Concrete Structures Standard (NZS 3101:1995), Standard Association of New Zealand, Willington, New Zealand, 1995, pp. 133-136.Google Search
16 
16.ACI-ASCE Committee 352, Recommendations for Design of Beam-Column Connections in Monolithic Reinforced Concrete Structures (ACI 352R-02), American Concrete Institute, Farmington Hills, Mich, 2002, pp. 1-37.Google Search
17 
17.Lin, C. M. and Restreop, J. I., “Seismic Behaviour and Design of Reinforced Concrete Interior Beam-Column Joints,” Bulletin of the New Zealand for Society Earthquake Engineering, Vol. 35, No. 2, 2002, pp. 108-128.Google Search
18 
18.Fu, J. P., Chen, T., Wang, Z., and Bai, S., “Effect of Axial Load Ratio on Seismic Behaviour of Interior Beam- Column Joints,” 12th World Conference on Earthquake Engineering, Auckland, New Zealand (12WCEE), 2000, pp. 1-5.Google Search
19 
19.Park, R. and Paulay, T., Reinforced Concrete Structures, John Wiley & Sons, 1975. pp. 11-47.DOI
20 
Google Search
21 
Google Search