Mobile QR Code QR CODE
Export citation EndNote
1 
1.Shah, S. P., “Do Fibers Increase the Tensile Strength of Cement-Based Matrixes,” ACI Materials Journal, Vol. 86, No. 6, 1991, pp. 595-602.Google Search
2 
2.Abrishami, H. H. and Mitchell, D., “Influence of Steel Fibers on Tension Stiffening,” ACI Structural Journal, Vol. 94, No. 6, 1997, pp. 769-776.Google Search
3 
3.Hong, C. W., Yun, K. K., Lee, J. H., and Park, J. S., “Development of Tension Stiffening Models for Steel Fibrous High Strength Reinforced Concrete Members,” Journal of the Korea Concrete Institute, Vol. 11, No. 6, 1999, pp. 35-46 (in Korean).Google Search
4 
4.Bischoff, P. H., “Tension Stiffening and Cracking of Steel Fiber-Reinforced Concrete,” ASCE Journal of Materials in Civil Engineering, Vol. 15, No. 2, 2003, pp. 174-182.DOI
5 
5.Lee, S. C., Kim, J. H., Cho, J. Y., and Shin, K. J., “Tension Stiffening od Reinforced High Performance Fiber Reinforced Cementitious Composites,” Journal of the Korea Concrete Institute, Vol. 22, No. 6, 2010, pp. 859-866 (in Korean).DOI
6 
6.Hameed, R., Turatsinze, A., Duprat, F., and Sellier, A., “A Study on the Reinforced Fibrous Concrete Elements Subjected to Uniaxial Tensile Loading,” KSCE Journal of Civil Engineering, Vol. 14, No. 4, 2010, pp. 547-556.DOI
7 
7.CEB-FIP, CEB-FIP Model Code 1990, Comite Euro-International Du Beton, Paris, 1991, pp. 247-251.Google Search
8 
8.European Committee for Standardization, Eurocode 2-Design of Concrete Structures, European Committee for Standardization, Brussels, 2002, pp. 124-131.Google Search
9 
9.Fields, K. and Bischoff, P. H., “Tension Stiffening and Cracking of High-Strength Reinforced Concrete Tension Members,”ACI Structural Journal, Vol. 101, No. 4, 2004, pp. 447-56.Google Search
10 
10.Yang, J. M., Yoon, S. H., Choi, S. J., and Kim, G. D., “Development and Application of Pig Iron Based Amorphous Fiber for Concrete Reinforcement,” Magazine of the Korea Concrete Institute, Vol. 25, No. 4, 2013, pp. 38-41 (in Korean).Google Search
11 
11.Ganesan, N., Indira, P. V., and Sabeeba, M. V., “Tension Stiffening and Cracking of Hybrid Fiber- Reinforced Concrete,” ACI Materials Journal, Vol. 110, No, 6, 2013, pp. 715-721.Google Search
12 
12.Kim, Y. S., Crack Spacings Relationship and Tension Stiffening Effect on Axially Loaded Tension Members Reinforced with Amorphous Steel Fibers, Department of Architectural Engineering, Gwangju University, Master's Thesis, 2014 (in Korean).Google Search
13 
13.CEB-FIP, CEB-FIP Model Code for Concrete Structures, Comite Euro-International Du Beton, 1978, 348pp.Google Search
14 
14.Lee, S. C., Cho, J. J., and Vecchio, F. J., “Tension Stiffening Model for Steel Fiber-Reinforced Concrete Containing Conventional Reinforcement,” ACI Structural Journal, Vol. 110, No. 4, 2013, pp. 639-648.Google Search
15 
15.Deluce, J. R., Lee, S. C., and Vecchio, F. J., “Cracking Model for Steel Fiber-Reinforced Concrete Members Containing Conventional Reinforcement,” ACI Structural Journal, Vol. 111, No. 1, 2014, pp. 93-102.Google Search
16 
16.Deluce, J. R. and Vecchio, F. J., “Cracking Behavior of Steel Fiber-Reinforced Concrete Members Containing Conventional Reinforcement,” ACI Structural Journal, Vol. 110, No. 3, 2013, pp. 481-490.Google Search
17 
17.Korea Concrete Institute, Structural Concrete Design Code, Kimoondang Publishing Company, Seoul, 2012, pp. 300-302 (in Korean).Google Search