JKCI
Journal of
the Korea Concrete Institute
KCI
Contact
Open Access
Bi-monthly
ISSN : 1229-5515 (Print)
ISSN : 2234-2842 (Online)
http://www.jkci.or.kr/jkci
Mobile QR Code
Journal of the Korea Concrete Institute
ISO Journal Title
J Korea Concr Inst.
SCOPUS
KCI Accredited Journal
Main Menu
Main Menu
저널소개
About Journal
최근호
Current Issue
논문집
All Issues
목적 및 범위
Aims and Scope
편집위원회
Editorial Board
논문투고안내
Instructions to Authors
출판정책
Publishing Policies
연락처
Contact Info
논문투고
Online-Submission
Journal Search
Home
All Issues
2014-10
(Vol.26 No.5)
10.4334/JKCI.2014.26.5.581
Journal XML
Export citation
EndNote
XML
PDF
INFO
REF
1
1.Shah, S. P., “Do Fibers Increase the Tensile Strength of Cement-Based Matrixes,” ACI Materials Journal, Vol. 86, No. 6, 1991, pp. 595-602.
2
2.Abrishami, H. H. and Mitchell, D., “Influence of Steel Fibers on Tension Stiffening,” ACI Structural Journal, Vol. 94, No. 6, 1997, pp. 769-776.
3
3.Hong, C. W., Yun, K. K., Lee, J. H., and Park, J. S., “Development of Tension Stiffening Models for Steel Fibrous High Strength Reinforced Concrete Members,” Journal of the Korea Concrete Institute, Vol. 11, No. 6, 1999, pp. 35-46 (in Korean).
4
4.Bischoff, P. H., “Tension Stiffening and Cracking of Steel Fiber-Reinforced Concrete,” ASCE Journal of Materials in Civil Engineering, Vol. 15, No. 2, 2003, pp. 174-182.
5
5.Lee, S. C., Kim, J. H., Cho, J. Y., and Shin, K. J., “Tension Stiffening od Reinforced High Performance Fiber Reinforced Cementitious Composites,” Journal of the Korea Concrete Institute, Vol. 22, No. 6, 2010, pp. 859-866 (in Korean).
6
6.Hameed, R., Turatsinze, A., Duprat, F., and Sellier, A., “A Study on the Reinforced Fibrous Concrete Elements Subjected to Uniaxial Tensile Loading,” KSCE Journal of Civil Engineering, Vol. 14, No. 4, 2010, pp. 547-556.
7
7.CEB-FIP, CEB-FIP Model Code 1990, Comite Euro-International Du Beton, Paris, 1991, pp. 247-251.
8
8.European Committee for Standardization, Eurocode 2-Design of Concrete Structures, European Committee for Standardization, Brussels, 2002, pp. 124-131.
9
9.Fields, K. and Bischoff, P. H., “Tension Stiffening and Cracking of High-Strength Reinforced Concrete Tension Members,”ACI Structural Journal, Vol. 101, No. 4, 2004, pp. 447-56.
10
10.Yang, J. M., Yoon, S. H., Choi, S. J., and Kim, G. D., “Development and Application of Pig Iron Based Amorphous Fiber for Concrete Reinforcement,” Magazine of the Korea Concrete Institute, Vol. 25, No. 4, 2013, pp. 38-41 (in Korean).
11
11.Ganesan, N., Indira, P. V., and Sabeeba, M. V., “Tension Stiffening and Cracking of Hybrid Fiber- Reinforced Concrete,” ACI Materials Journal, Vol. 110, No, 6, 2013, pp. 715-721.
12
12.Kim, Y. S., Crack Spacings Relationship and Tension Stiffening Effect on Axially Loaded Tension Members Reinforced with Amorphous Steel Fibers, Department of Architectural Engineering, Gwangju University, Master's Thesis, 2014 (in Korean).
13
13.CEB-FIP, CEB-FIP Model Code for Concrete Structures, Comite Euro-International Du Beton, 1978, 348pp.
14
14.Lee, S. C., Cho, J. J., and Vecchio, F. J., “Tension Stiffening Model for Steel Fiber-Reinforced Concrete Containing Conventional Reinforcement,” ACI Structural Journal, Vol. 110, No. 4, 2013, pp. 639-648.
15
15.Deluce, J. R., Lee, S. C., and Vecchio, F. J., “Cracking Model for Steel Fiber-Reinforced Concrete Members Containing Conventional Reinforcement,” ACI Structural Journal, Vol. 111, No. 1, 2014, pp. 93-102.
16
16.Deluce, J. R. and Vecchio, F. J., “Cracking Behavior of Steel Fiber-Reinforced Concrete Members Containing Conventional Reinforcement,” ACI Structural Journal, Vol. 110, No. 3, 2013, pp. 481-490.
17
17.Korea Concrete Institute, Structural Concrete Design Code, Kimoondang Publishing Company, Seoul, 2012, pp. 300-302 (in Korean).