JKCI
Journal of
the Korea Concrete Institute
KCI
Contact
Open Access
Bi-monthly
ISSN : 1229-5515 (Print)
ISSN : 2234-2842 (Online)
http://www.jkci.or.kr/jkci
Mobile QR Code
Journal of the Korea Concrete Institute
ISO Journal Title
J Korea Concr Inst.
SCOPUS
KCI Accredited Journal
Main Menu
Main Menu
저널소개
About Journal
최근호
Current Issue
논문집
All Issues
목적 및 범위
Aims and Scope
편집위원회
Editorial Board
논문투고안내
Instructions to Authors
출판정책
Publishing Policies
연락처
Contact Info
논문투고
Online-Submission
Journal Search
Home
All Issues
2017-08
(Vol.29 No.4)
10.4334/JKCI.2017.29.4.345
Journal XML
Export citation
EndNote
XML
PDF
INFO
REF
1
Kim, J. K., Han, B. S., and Shin, S. W., “Ductility Capacity of Ultra-High Strength R/C Tied Columns Considering the Axial Load Ratio and Configuration of Transverse Reinfor-cement”, Architectural Institute of Korea, Vol. 25, No. 1, 2009, p. 503.
2
ACI Committee 318, Building Code Requirements for Struc-tural Concrete (ACI 318M-14) and Commentary, American Concrete Institute, Farmington Hills, Michigan, USA, 2014, p. 519.
3
Yang, K. H., Lee, Y. H., Kwak, N. H., and Chung, H. S., “A Study on the Effectiveness of Hook Type of Crossties in the Flexural Behavior of Confined Concrete Columns”, Journal of the Architectural Institute of Korea, Vol. 15, No. 9, 1999, pp. 63-70.
4
Lukkunaprasit, P. and Sittipunt, C., “Ductility Enhancement of Moderately Confined Concrete Tied Columns with Hook-Clips”, ACI Structural Journal, Vol. 100, No. 4, 2003, pp. 422-429.
5
Yang, K. H. and Kim, W. W., “Axial Compression Perfor-mance of RC Short Columns with Supplementary V-Shaped Ties”, ACI Structural Journal, Vol. 113, No. 6, 2016, pp. 1347-1356.
6
ACI Committee 318, Building Code Requirements for Structu-ral Concrete(ACI 318M-14) and Commentary, American Concrete Institute, Farmington Hills, Michigan, USA, 2014, p. 503.
7
Kwak, M. K. and Yang, K. H., “Simplified Moment-Curvature Relationship Model of Reinforced Concrete Columns Consi-dering Confinement Effect”, Magazine of Concrete Research, Vol. 28, No. 3, 2016, pp. 279-288.
8
FEMA 356, Prestandard and Commentary for the Seismic Rehabilitation of Buildings, FEMA, Washington, 2000.
9
Yang, K. H., “Flexural Behavior of Reinforced Concrete Columns Using Wire Ropes as Lateral Reinforcement”, Magazine of Concrete Research, Vol. 64, No. 3, 2012, pp. 269-281.
10
Watson, S. and Park, R., “Simulated Seismic Load Tests on Reinforced Concrete Columns”, Journal of Structural Engi-neering, Vol .120, No. 6, 1994, pp. 1825-1849.
11
Sheikh, S. A. and Khoury, S. S., “A Performance-Based Approach for the Design of Confining Steel in Tied Columns”, ACI Structural Journal, Vol. 94, No. 4, 1997, pp. 421-432.
12
MacGregor, J. G., Reinforced Concrete Mechanics and Design, 2011, pp. 576-589.