Mobile QR Code QR CODE
Export citation EndNote

References

1 
ACI Committee 374 , 2013, Guide for Testing Reinforced Concrete Structural Elements Under Slowly Applied Simulated Seismic Loads (ACI 374.2R-13), Farmington Hills, Michigan, US; American Concrete Institute (ACI), pp. 1-22Google Search
2 
ASTM D 638-14 , 2014, Standard Test Method for Tensile Properties of Plastics, West Conshohocken, PA; ASTM International, pp. 1-17Google Search
3 
Cho C. M., Lee D. S., Kim T. K., Kim J.-H. J., 2017, Pseudo Dynamic Test Study on Seismic Performance Evaluation of RC Columns Retrofitted by PolyUrea, Journal of the Korean Society of Civil Engineers, Vol. 37, No. 2, pp. 289-301. (In Korean)DOI
4 
Ho J. C. M., 2003, Inelastic Design of Reinforced Concrete Beams and Limited Ductile High-Strength Concrete Columns, Ph.D. Thesis. The University of Hong KongGoogle Search
5 
Jang H. K., Im C. S., Cho C. H., 1999, Strength and Ductility of Reinforced Concrete Columns strengthened with steel plate, Journal of the Architectural Institute of Korea, Vol. 15, No. 2, pp. 81-87. (In Korean)Google Search
6 
Kim J. S., Seo H. S., Lim J. H., Kwon M. H., 2014, An Performance Evaluation of Seismic Retrofitted Column Using FRP Composite Reinforcement for Rapid Retrofitting, Journal of the Korea Concrete Institute, Vol. 26, No. 1, pp. 47-55. (In Korean)DOI
7 
Kim J.-H. J., Park J. C., Lee S. W., Kim S. B., 2011, Evaluation of Strengthening Performance of Stiff Type Polyurea Retrofitted RC Slab Based on Attachment Procedure, Journal of the Korea Concrete Institute, Vol. 23, No. 4, pp. 511-520. (In Korean)DOI
8 
KMA , 2018, 2017 Earthquake Annual Report, Seoul, Korea; Korea Meteorological Administration (KMA). (In Korean)Google Search
9 
Korea Agency for Technology and Standards (KATS) , 2007, Polyurea Resin Waterproofing Membrane Coating (KS F 4922), Seoul, Korea: Korea Standard Association (KSA). (In Korean)Google Search
10 
Korea Agency for Technology and Standards (KATS) , 2017, Standard Test Method for Compressive Strength of Concrete (KS F 2405), Seoul, Korea: Korea Standard Association (KSA). (In Korean)Google Search
11 
Korea Agency for Technology and Standards (KATS) , 2018, Method of Tensile Test for Metallic Materials (KS B 0802), Seoul, Korea: Korea Standard Association (KSA). (In Korean)Google Search
12 
Korea Infrastructure Safety & Technology Corporation (KISTEK) , 2013, Assessment of Seismic Performance of Existing Facilities (Buildings) (RD-13-R3-058), Sejong, Korea; Ministry of Land, Infrastructure and Transport (MOLIT). (In Korean)Google Search
13 
Kukdo Chemical Co., Ltd. , 2007, Specification of Polyurea Coating Material (POLYDO KPU-300A/B), Seoul, Korea; Kukdo Chemical Co., Ltd. (In Korean)Google Search
14 
MOIS , 2018, Details of Seismic Reinforcement, Sejong, Korea; Ministry of the Interior and Safety (MOIS). (In Korean)Google Search
15 
Yu E., 2015, Seismic Performance and Retrofit of Masonry- infilled Frames, Magazine of the Korea Concrete Institute, Vol. 27, No. 6, pp. 41-45. (In Korean)DOI