Mobile QR Code QR CODE
Export citation EndNote

References

1 
Abaqus, V. (2014) 6.14 Documentation. RI, USA: DS SIMULIA Corp. 651(6.2).URL
2 
Abrishambaf, A., Barros, J. A., and Cunha, V. M. (2015) Tensile Stress-Crack width Law for Steel Fibre Reinforced Self-Compacting Concrete Obtained from Indirect (Splitting) Tensile Tests. Cement and Concrete Composites 57, 153-165.DOI
3 
ACI Committee 318 (2014) Building Code Requirements for Reinforced Concrete (ACI 318-14) and Commentary (ACI 318R-14). Farmington Hills, MI: American Concrete Institute (ACI), 518.URL
4 
Bae, B. I., Choi, H. K., and Choi, C. S. (2015) Correlation between Tensile Strength and Compressive Strength of Ultra High Strength Concrete Reinforced with Steel Fiber. Journal of the Korea Concrete Institute 27(3), 235-263. (In Korean)URL
5 
Cao, X., Wu, L., and Li, Z. (2020) Behaviour of Steel-Reinforced Concrete Columns under Combined Torsion Based on ABA QUS FEA. Engineering Structures 209, 109980.DOI
6 
Denneman, E., Kearsley, E. P., and Visser, A. T. (2011) Splitting Tensile Test for Fibre Reinforced Concrete. Materials and Structures 44(8), 1441-1449.DOI
7 
Faisal, N. H., Mann, L., Duncan, C., Dunbar, E., Clayton, M., Frost, M., McConnachie, J., Fardan, A., and Ahmed, R. (2019) Diametral Compression Test Method to Analyse Relative Surface Stresses in Thermally Sprayed Coated and Uncoated Circular Disc Specimens. Surface and Coatings Technology 357, 497-514.DOI
8 
Gao, W. Y., Dai, J. G., Teng, J. G., and Chen, G. M. (2013) Finite Element Modeling of Reinforced Concrete Beams Exposed to Fire. Engineering Structures 52, 488-501.DOI
9 
Genikomsou, A. S., and Polak, M. A. (2014) Finite Element Analysis of a Reinforced Concrete Slab-Column Connection Using ABAQUS. In Structures Congress 2014 (pp. 813-823).DOI
10 
Hamid, S., Mahdi, S., Amir, H. A., Mohammad, A., and Ali, S. (2012) Evaluation of Reinforced Concrete Beam Behaviour Using Finite Element Analysis by ABAQUS. Scientific Research and Essays 7(21), 2002-2009.URL
11 
King, S., and Richards, T. (2013) Solving Contact Problems with Abaqus. In Abaqus Contact Seminar Available Online https:// swym.3ds.com, DS UK Ltd., Coventry (pp. 1-325).URL
12 
Martin, J., Stanton, J., Mitra, N., and Lowes, L. N. (2007) Experimental Testing to Determine Concrete Fracture Energy Using Simple Laboratory Test Setup. ACI Materials Journal 104(6), 575.URL
13 
Momoh, E. O., Osofero, A. I., and Menshykov, O. (2022) Behaviour of Clamp-Enhanced Palm Tendons Reinforced Concrete. Construction and Building Materials 341, 127824.DOI
14 
Seok, S., Haikal, G., Ramirez, J. A., Lowes, L. N., and Lim, J. (2020) Finite Element Simulation of Bond-Zone Behavior of Pullout Test of Reinforcement Embedded in Concrete Using Concrete Damage-Plasticity Model 2 (CDPM2). Engineering Structures 221, 110984.DOI
15 
Taerwe, L., and Matthys, S. (2013) Fib Model Code for Concrete Structures 2010. Berlin, Germany: Ernst & Sohn, Wiley. doi: 10.1002/9783433604090.DOI
16 
Taylor, R. L., and Papadopoulos, P. (1991) On a Patch Test for Contact Problems in Two Dimensions. Computational Methods in Nonlinear Mechanics 690, 702.URL
17 
Walker, S., and Bloem, D. L. (1960) Effects of Aggregate Size on Properties of Concrete. Journal Proceedings 57(9), 283-298.URL
18 
Yang, K. H., Mun, J. H., Cho, M. S., and Kang, T. H. (2014) Stress-Strain Model for Various Unconfined Concretes in Compression. ACI Structural Journal 111(4), 819.URL
19 
Zhang, D., Wang, Q., and Dong, J. (2016) Simulation Study on CFRP Strengthened Reinforced Concrete Beam under Four- Point Bending. Computers and Concrete 17(3), 407-421.URL