Mobile QR Code QR CODE : Journal of the Korean Society of Civil Engineers
Title Fire Damage Assessment for Steel-Concrete Composite and PSC Bridge Superstructures Using Heat Flow Analysis
Authors 박양흠(Park, Yang Heum) ; 윤성환(Yun, Sung-Hwan) ; 장일영(Jang, Il Young)
DOI https://doi.org/10.12652/Ksce.2021.41.2.0093
Page pp.93-100
ISSN 10156348
Keywords 강합성 교량 상부구조;PSC 교량 상부구조;열유동 해석;화재손상평가 Steel-concrete composite bridge superstructure;PSC bridge superstructure;Heat flow analysis;Fire damage evaluation
Abstract The objective of this research is to evaluate of fire damage for steel-concrete composite bridge superstructure and PSC bridge superstructure under highway bridge exposed to fire loading. To enhance the accuracy and efficiency of the numerical analysis, the proposed heat flow fire analysis method is implemented in ANSYS. The proposed heat flow analysis method is applied to fire damage analysis and performance evaluation for Buchen and Yangsan highway bridge. The result of analysis, temperature of concrete slab and lower flange of steel-concrete composite bridge superstructure are exceed the critical temperature. Also, temperature of slab, lower and upper flange, web of PSC bridge superstructure are exceed the critical temperature. However, the major component, tendon, did not exceed the critical temperature.