Mobile QR Code QR CODE : Journal of the Korean Society of Civil Engineers
1 
ANSI/HI 1.3 (2000). Centrifugal pumps for design and application, American National Standards Institute, pp. 11-21.
2 
ANSI/HI 9.6.3 (1997). Centrifugal and vertical pumps for allowable operating region, American National Standards Institute, pp. 1. 10.1016/S0262-1762(97)91261-X DOI
3 
Badruzzaman, M., Voutchkov, N., Weinrich, L. and Jacangelo, J. G. (2019). "Selection of pretreatment technologies for seawater reverse osmosis plants: A review." Desalination, Vol. 449, pp. 78-91. 10.1016/j.desal.2018.10.006 DOI
4 
Bernat, X., Gibert, O., Guiu, R., Tobella, J. and Campos, C. (2010). The economics of desalination for various uses, Re-thinking Water and Food Security: Fourth Botín Foundation Water Workshop, CRC Press, Florida, USA, pp. 329-346.
5 
Fritzmann, C., Löwenberg, J., Wintgens, T. and Melin, T. (2007). "State of-the-art of reverse osmosis desalination." Desalination, Vol. 216, No. 1-3, pp. 1-76. 10.1016/j.desal.2006.12.009 DOI
6 
Gille, D. (2003). "Seawater intakes for desalination plants." Desalination, Vol. 156, No. 1-3, pp. 249-256. 10.1016/S0011-9164(03)00347-3 DOI
7 
Global Water Intelligence (2015). Desalination markets 2016.
8 
Greenlee, L. F., Lawler, D. F., Freeman, B. D., Marrot, B. and Moulin, P. (2009). "Reverse osmosis desalination: water sources, technology, and today's challenges." Water research, Vol. 43, No. 9, pp. 2317-2348. 10.1016/j.watres.2009.03.010 19371922 DOI
9 
Hashimoto, T., Stedinger, J. R. and Loucks, D. P. (1982). "Reliability, resiliency, and vulnerability criteria for water resources system performance evaluation." Water Resources Research, Vol. 18, No. 1, pp. 14-20. 10.1029/WR018i001p00014 DOI
10 
Jamaly, S., Darwish, N. N., Ahmed, I. and Hasan, S. W. (2014). "A short review on reverse osmosis pretreatment technologies." Desalination, Vol. 354, pp. 30-38. 10.1016/j.desal.2014.09.017 DOI
11 
Kurihara, M. and Takeuchi, H. (2013). "Mega-ton water system: Japanese national research and development project on seawater desalination and wastewater reclamation." Desalination, Vol. 308, pp. 131-137. 10.1016/j.desal.2012.07.038 DOI
12 
K-water (2019). The feasibility and basic plan for SWRO project in Daesan industrial area, pp. 6-155, 6-179, 6-189, 6-192 (in Korean).
13 
Sauvet-Goichon, B. (2007). "Ashkelon desalination plant-A successful challenge, desalination." Desalination, Vol. 203, No. 1-3, pp. 75-81. 10.1016/j.desal.2006.03.525 DOI
14 
Suh, S. H., Kim, K. W., Kim, H. H., Yoon, I. S. and Cho, M. T. (2015). "Evaluation of energy saving with vector control inverter driving centrifugal pump system." The KSFM Journal of Fluid Machinery, Vol. 18, No. 2, pp. 67-72 (in Korean). 10.5293/kfma.2015.18.2.067 DOI
15 
Villacorte, L.O., Tabatabai, S. A. A., Dhakal, N., Amy, G., Schippers, J. C. and Kennedy M. D. (2014). "Algal blooms: an emerging threat to seawater reverse osmosis desalination." Desalination and Water Treatment, Vol. 55, pp. 2601-2611. 10.1080/19443994.2014.940649 DOI
16 
Voutchkov, N. (2010) Desalination engineering: Planning and design, McGraw-Hill, New York, USA, pp. 17, 73, 115.
17 
Voutchkov, N. (2018). "Energy use for membrane seawater desalination - current status and trends." Desalination, Vol. 431, pp. 2-14. 10.1016/j.desal.2017.10.033 DOI
18 
Woo, S. W. and Kim, Y. H. (2017). "Reduction of power consumption by variable speed operation of high pressure pump in seawater reverse osmosis desalination plant." The KSFM Journal of Fluid Machinery, Vol. 20, No. 5, pp. 33-39 (in Korean). 10.5293/kfma.2017.20.5.033 DOI