Title |
LQG Hybrid Vibration Control of a Structure Using TMD
|
Keywords |
하이브리드 제진 ; 능동제어 ; Linear Quadratic Gaussian(LQG) 제어 TMD ; Passive control ; Active Control ; Linear Quadratic Gaussian(LQG) ; Kalman Filter |
Abstract |
The purpose of this study is to investigate the effectiveness of a LQG Hybrid controller to suppress the earthquake disturbance for the building structure. The ground acceleration of N-S component of El-Centro earthquake was scaled to confirm that the building behaved within the elastic range. The tuned mass damper(TMD) on the top floor regulated by LQG algorithm was designed to control the floor displacements. The displacement responses of the hybrid control were compared with those obtained from an active control along with a passive control. The results showed that the LQG hybrid control used approximately 50% less input forces than an active control to satisfy the performance criteria.
|