Mobile QR Code QR CODE

Journal of the Korea Concrete Institute

J Korea Inst. Struct. Maint. Insp.
  • Indexed by
  • Korea Citation Index (KCI)
Title Determination of the Initial Tendon Force in Two-span Continuous Steel-Concrete Composite Beam Strengthened with External Tendons
Authors 최동호 ; 유동민 ; 정재동 ; 김은지
Page pp.145-152
ISSN 1226-6205
Keywords 외부 긴장재 ; 2경간 연속 강합성보 ; 내하율 ; 초기 긴장력 External tendon ; Two-span continuous composite beam ; Rating factor ; Initial tendon force
Abstract This paper presents a method to enhance the load carrying capacity for a two-span continuous steel-concrete composite beam strengthened with external tendons. The tendon is placed at the bottom of steel beam where the positive bending moment occurs. This results in the reduction of the negative bending moment as well as the positive bending moment. This paper describes the procedure to determine the number of tendon and the initial tendon force for the target rating factor in the rating factor equation. An example beam is given to demonstrate the proposed procedure, and it validity is confirmed.