Title |
Shotcrete-Retrofit of Shear Walls with an Opening
|
Keywords |
전단벽 ; 개구부 ; 리모델링 ; 숏크리트 ; 섬유보강콘크리트 Shear wall ; Opening ; Remodeling ; Shotcrete ; ECC |
Abstract |
Because of the characteristics relating to high tensile ductility, High Performance Fiber Reinforced Cementitious Composites (HPFRCC) are studied to be adopted in repair and retrofit of buildings. A series of three shear wall specimens was tested under constant axial stress and reversed cyclic lateral loading in order to evaluate the seismic retrofit that had been proposed for the shear wall with the opening. The retrofit involved the use of newly developed ECC and MDF(Macro Defect Free), both of which are sprayed through the high pressure pump, over the entire face of the wall. The results indicate that two difference types of retrofitting strategy make the different effects of a rise in the strength and ductility of each specimen.
|