Title |
A Study on the Properties of Ready Mixed Concrete Quality in Site by Statistical Analysis
|
Keywords |
레디믹스트 콘크리트(레미콘) ; 통계적 분석 ; 슬럼프 ; 압축강도 ; Ready mixed concrete ; Statistical analysis ; Slump ; Compressive strength |
Abstract |
The quality of ready-mixed concrete(henceforth abbreviated remicon) is influenced by various factors such as ingredient of material, difference of property, mixing ratio, mixing time, mixing error, conditioning of construction, method of curing and temperature, humidity time in transportation. These factors make it hard to confirm the quality of remicon till placing in site. As the quality control in field is very important to ensure the quality of building. Moreover in modern building production, the more important the inquiry of performance improvement, the more important the manufacture and the quality control of remicon. In this study, to examine and analyze the quality of remicon we used slump, air content and compressive strength in 7, 28 days as to remicon which placed during on year. As a result, we found that the slump and air content were satisfied with reference code and the compressive strength was more than the design standard strength so we concluded that the quality control of remicon was to be agreeable.
|