Keywords |
SD500 고강도 철근 ; 강관 스플라이스 슬리브 ; 구조성능 High strength rebar(SD500) ; Steel pipe splice sleeve ; Structural performance |
Abstract |
Among several splicing system of reinforcing bar the grout-filled splice sleeve system has been applied widely. However. as the splice sleeve for high strength rebar as SD500 is not yet made in korea. the development of splice sleeve for high strength reinforcing bar are required as soon as possible. It is the purpose of this study to develop the steel pipe sleeve for high strength rebar as SD500 and estimate its structural performance by monotonic loading test. The experimental variables adopted in this study are the development length of rebars. types of sleeve etc. The results of this study showed that the developed steel pipe splice sleeve system for high strength reinforcing bar as SD500 retained the structural performance required in domestic. ACI and AIJ criteria. And it is considered that the study result presented in this paper can be helpful in developing reasonable design method of steel pipe splice sleeve system for high strength reinforcing bar as SD500
|