Keywords |
외부 강선 ; 유도초음파 ; 긴장력 ; 계측 ; External tendon ; Deriving ultrasonic pulse ; Tendon force. Measure |
Abstract |
In domestic case, there are no results of corresponding researches for measuring external tendon force. The purpose of the present paper is therefore to measure external tendon force by using deriving ultrasonic method. For this purpose, we designed and manufactured wedges and test system, and measured ultrasonic pulse velocity and pulse amplitude. By using measured data. we tried to analyze the characteristics of tendon force, and to derive the relationship between tendon force and ultrasonic pulse velocity. finally to develop the technic of measuring system using ultrasonic pulse velocity. So tendon force-velocity relationship was proposed by equations, and those equations of which errors were 3.92-8.77% will be possible to adapt in-site.
|