Title |
Regarding a Shear Strengthening of an Epoxy Mortar Panel for RC Beam Without Shear Strengthening Reinforcing Bar
|
Keywords |
탄소섬유시트 ; 에폭시 모르타르 패널 ; 철근콘크리트 보부재 ; 전단보강 CFS ; Epoxy Mortar Panel ; Reinforced Concrete Beam ; Shear Strengthening |
Abstract |
In this study, the effect of epoxy mortar panel as the shear strengthening material of reinforced concrete beam is investigated by loading test. The main variables are the kind of strengthening material. the amount of reinforcement and the spacing of CFS(Carbon Fiber Sheet) stirrups. The design method to use epoxy mortar panel as shear strengthening of reinforced concrete beam took the shear capacity as the form of the sum of Vc, Vs, Vsheet and Vp. By making a comparison between the values calculated by the proposed shear strength prediction formula and those from the loading test results, the mean value was 1.10 and the standard deviation was 8.16%.
|