Title |
Behavior of Coupling Shear Wall with New Openings
|
Keywords |
연결보 ; 연결 슬래브 ; 개구부 ; 리모델링 ; 전단벽 Coupling beam ; Coupling slab ; Opening ; Remodeling ; Shear wall |
Abstract |
Since wall system apartment used the shear wall as main lateral resistance member, installation of openings which causing section loss of walls may cause significant problem to structure. Also, there are few studies for inducing coupling beam or slabs which are occurred by installing openings. Therefore, this study planned isolated 2-story shear walls which are reduced three half-scale specimen to find out walls behavior characteristic. The test results showed that strength reduction caused by loss of effective section of walls and different result of stiffness and energy dissipation regarding to the coupling beam and coupling slabs.
|