Title |
Characteristics of Temperature Distribution of Axially Loaded CFT Column with Fire Protection
|
Keywords |
내화성능 ; 온도분포특성 ; 내화피복 ; 열적특성 Fire resistance performance ; Temperature distribution characteristic ; Fire protection ; Thermal properties |
Abstract |
When the fire occur, concrete filled steel tube(CFT) columns expected to form a much distinction in a fire resistance performance according to a kind of fire protection because the steel surface is directly exposed to high temperature. In this study, an experiment by three factors which were kind of fire protection, thickness of protection and time was performed to get the characteristics of temperature distribution types of CFT column with fire protection. As the result of this study, on a basis of heating temperature, spray protection was the most superior in a fire resistance performance, fireproof paint was next, and without fire protection was most inferior. In a heating time-location relationship, the temperature increased slowly on the surface of the concrete, but the temperature increased sharply on the surface of the steel.
|