Mobile QR Code QR CODE

Journal of the Korea Concrete Institute

J Korea Inst. Struct. Maint. Insp.
  • Indexed by
  • Korea Citation Index (KCI)
Title Flexural Behavior of Hybrid Fiber Reinforcement Strengthened RC Beams
Authors 이성태 ; 이진용
Page pp.79-86
ISSN 1226-6205
Keywords 하이브리드 섬유보강재 ; HFC ; HFB ; 휨거동 ; 철근콘크리트 보 Hybrid fiber reinforcement ; HFC ; HFB ; Flexural behavior ; RC beams
Abstract This study was performed to evaluate the flexural behavior of Hybrid fiber sheet (HFC) and Hybrid fiber bar (HFB) strengthened reinforced concrete (RC) beams. According to test results, Hybrid fiber reinforcement strengthened RC beams showed approximately 60 to 200% higher reinforcing effects than that of un-reinforced specimens. In addition, the reinforced beams showed the ideal failure pattern, which is failed presenting the ductile behavior after yielding of the reinforcing bar. More specifically, in the case of HFB reinforced RC beams, the difference with puttying method was not apparent since HFB beams reinforced using the injection of epoxy and bonding of putty showed the similar failure patterns.