Title |
Seismic Performance Evaluation of Nonseismic Neighborhood Living Facilities Considering Deterioration
|
Authors |
이영천 ; 정채명 ; 이은진 ; 김명훈 ; 최기봉 |
Keywords |
내진 설계 ; 노후도 고려 ; 내진성능평가 ; 내진보강 ; 비선형 정적 해석 Seismic designed ; Deterioration ; Seismic performance evaluation ; Seismic retrofit ; Nonlinear static analysis |
Abstract |
In this study, seismic performance was evaluated considering the deterioration level for the low-rise and moderate buildings with non-seismic details which are most common in Korea. Evaluation results showed that the deterioration condition is relatively good even after 24 years of construction but the seismic performance did not satisfy the protection index in the first and second evaluation. In case of the third evaluation, the goal performance was satisfied based on the interstory drift ratio but reinforcement is found to be necessary. Seismic performance was evaluated after the target buildings were reinforced in the walls, bracing, and damper. Results showed the interstory drift ratio drastically reduced regardless of reinforcement methods and satisfied the level of immediate occupancy. In case of wall reinforcement, however, base shear increased more than double which requires review on the existing foundation.
|