Mobile QR Code QR CODE

Journal of the Korea Concrete Institute

J Korea Inst. Struct. Maint. Insp.
  • Indexed by
  • Korea Citation Index (KCI)
Title Survey Research on Thermal Situation of Office Buildings
Authors 정의인 ; 김봉주
Page pp.145-152
ISSN 1226-6205
Keywords 커튼월 ; 프레임 ; 멀리온 바 ; 스팬드럴 바 ; 앵커유닛 ; 열교 Curtain wall ; Frame ; Mullion bar ; Spandrel bar ; Anchor unit ; Heat bridge
Abstract This study is to evaluate the thermal insulation of the curtain wall of the buildings constructed since the 1990s to the buildings currently under construction in 2011 and to provide the basic data for repairing and reinforcing and designing the thermal insulation. To this effect, the temperature difference by part was analyzed through measuring the inside and outside surface temperature of the curtain wall of the office building, and thereafter, the conditions of the thermal insulation and the thermal bridge part were examined. The result of the study is as follows; Not only in the winter season when the temperature difference between the indoor-outdoor is over 20℃, but also in the summer season when there is a small temperature difference, the temperature difference between the inside and outside of the frame is 2℃~4℃ equally. Under such conditions as stated above, the thermal bridge occurred, which resulted from the heat flow of the steel frame part (mullion, transom), and therefore, the reinforcement of the thermal insulation is considered to be needed.