Mobile QR Code QR CODE

Journal of the Korea Concrete Institute

J Korea Inst. Struct. Maint. Insp.
  • Indexed by
  • Korea Citation Index (KCI)
Title Failure Behavior of Octagonal Flared RC Columns Using Oblong Hoops
Authors 고성현
DOI jksmi.2014.18.3.058
Page pp.58-68
ISSN 2234-6937
Keywords 플레어 기둥 ; 장방형 단면 ; 장방형 후프 띠철근 ; 횡구속 방법 ; 강축 Flared column ; Oblong cross-section ; Oblong hoop ; Lateral confinement method ; Strong axis
Abstract Transverse steel bars are used in the plastic hinge zone of columns to insure adequate confinement, prevention of longitudinal bar buckling and ductile behavior. Fabrication and placement of rectangular hoops and cross-ties in columns are difficult to construct and require larger amount of transverse steels. In this paper, to solve these problems, the new lateral confinement method using oblong hoop is proposed for the transverse confinement of columns of the oblong cross-section and flared column. The experimental study for octagonal oblong cross-section was carried out by the flared columns test in strong axis. The lateral confinement method using proposed oblong hoop detail showed satisfactory performance of lateral confinement. Therefore it can be the alternative for oblong cross-section and flared column with improved workability and cost-efficiency.